shoping-cartYour cart is empty
    Sign In or Register



    Sign In Socially

    If you are a member of facebook or google or yahoo, you can login to our system by clicking on the icon below.


EJA110E-JHB5G-72DDK/KS21/M01/T12/D3 New Yokogawa EJA110E Differential Pressure Transmitter

EJA110E-JHB5G-72DDK/KS21/M01/T12/D3 New Yokogawa EJA110E Differential Pressure Transmitter

$3,484.00  $1,707.00
Save: 51% off


Part Number: EJA110E-JHB5G-72DDK/KS21/M01/T12/D3
Model: EJA110E Differential Pressure Transmitter
Brand: Yokogawa
Condition: New & Original in Factory Packing
Factory Warranty: 12 Months

EJA110E features include:
  • 0.055% Accuracy (0.04% Accuracy optional)
  • 0.1% Stability per 10 years
  • 90 ms Response Time
  • Exida and TUV SIL 2 / SIL3 Certified
  • MWP 2,300 psi (MWP 3,600 psi option)
  • Local Parameter Setting (LPS)

Model and Suffix Codes

Model EJA110E Differential pressure transmitter
Output signal -J 4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)(1)
Measurement span (capsule) H 5 to 500 kPa (20 to 2000 inH2O)
Wetted parts material(2) B# Cover flange and process connector: Monel equivalent(3)
Capsule: Monel
Capsule gasket: PTFE Teflon
Vent/Drain plug: Monel
Process connections *5 without process connector (1/4 NPT female on the cover flanges)
Bolts and nuts material G 316L SST
Installation -7 Vertical piping, left side high pressure, and process connection downside
Amplifier housing 2 ASTM CF-8M stainless steel(4)
Electrical connection D M20 female, two electrical connections and a SUS316 blind plug
Integral indicator D Digital indicator(5)
Mounting bracket K 316 SST or SCS14A 2-inch pipe mounting, L type (for vertical piping)
ATEX KS21 ATEX Intrinsically safe Approval(6)(7)
   Applicable Standard: EN 60079-0:2012/A11:2013, EN 60079-11:2012, EN 60079-26:2007
   Certificate: DEKRA 11ATEX0228 X
   II 1G, 2D Ex ia IIC T4 Ga, Ex ia IIIC T85??C T100??C T120??C Db
   Degree of protection: IP66/IP67
   Amb. Temp. (Tamb) for EPL Ga: ?C50 to 60??C (?C58 to 140??F)
   Maximum Process Temp. (Tp) for EPL Ga:120??C
   Electrical data: Ui=30 V, Ii=200 mA, Pi=0.9 W, Ci=27.6 nF, Li=0 ??H
   Amb. Temp. for EPL Db: ?C30 to 60??C(8)
   Max. surface Temp. for EPL Db: T85??C (Tp: 80??C), T100??C (Tp: 100??C), T120??C (Tp: 120??C)
Material certificate(9) M01 Cover flange(10)
Pressure test/ Leak test certificate(11)T12 Test Pressure: 16 MPa(2300 psi)
Nitrogen(N2) Gas(12)
Retention time: one minute
Calibration units(13) D3 bar calibration (bar unit)

The ??*?? marks indicate the most typical selection for each specification.
  1. HART 5 or HART 7 is selectable. Specify upon ordering
  2. Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user??s process fluids.
    Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150??C [302??F] or above). Contact Yokogawa for detailed information of the wetted parts material.
  3. Indicated material is equivalent to ASTM M35-2.
  4. Not applicable for electrical connection code 0, 5, 7 and 9.
  5. Not applicable for output signal code G.
  6. Applicable for Electrical connection code 2, 4, 7, 9, C and D.
  7. Not applicable for output signal code Q.
  8. Lower limit of ambient temperature is ?C15??C (5??F) when option code HE is specified.
  9. Material traceability certification, per EN 10204 3.1B.
  10. Applicable for process connections codes 0 and 5.
  11. The unit on the certificate is always Pa unit regardless of selection of option code D1, D3 or D4.
  12. Pure nitrogen gas is used for oil-prohibited use (option codes K1, K2, K5, and K6).
  13. The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by option codes D1, D3, and D4.


  • Estimated Lead Time: 10 - 14
  • Shipping Weight: 10 Kg

Add to Cart:

  • Model: EJA110E-JHB5G-72DDK/KS21/M01/T12/D3
  • 7 Units in Stock


Processing Time
  • Ships in 24 hours: Processing Time is guaranteed to be shorter than 24 hours.
  • Typical Processing Time: 3 - 12 days

We ship to over 200 countries worldwide!