shoping-cartYour cart is empty
    Sign In or Register



    Sign In Socially

    If you are a member of facebook or google or yahoo, you can login to our system by clicking on the icon below.


EJA118E-FHSCG-919DN-WA43C1SW00-CA25/KF25/M2W/T58 New Yokogawa EJA118E Diaphragm Sealed Differential Pressure Transmitter

EJA118E-FHSCG-919DN-WA43C1SW00-CA25/KF25/M2W/T58 New Yokogawa EJA118E Diaphragm Sealed Differential Pressure Transmitter

$5,518.00  $2,703.00
Save: 51% off


Part Number: EJA118E-FHSCG-919DN-WA43C1SW00-CA25/KF25/M2W/T58
Model: EJA118E Diaphragm Sealed Differential Pressure Transmitter
Manufacturer: Yokogawa
Condition: New & Original in Factory Packing
Factory Warranty: 12 Months

Description
The EJA-E series of transmitters is Yokogawa's most recent evolution of the DPharp family. Released in 2012, it combines the ruggedness and success of the work-horse EJA-E series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa.

The EJA118E is a Differential Pressure Transmitter with remote diaphragm seals.

EJA118E features include:
  • ??0.2% Accuracy
  • 200 ms Response Time
  • Exida and TUV SIL2 / SIL3 Certified
  • Local Parameter Setting (LPS)
  • 10-segment Signal Characterizer
  • Active Capillary Fill Fluid Density Compensation

Model and Suffix Codes

Model EJA118E Diaphragm sealed differential pressure transmitter
Output signal -F Digital communication (FOUNDATION Fieldbus protocol, refer to GS 01C31T02-01EN)
Measurement span (capsule) H 25 to 500 kPa (100 to 2000 inH2O)
S Always S
C Always C
Cover flange bolts and nuts material G 316L SST
Installation -9 Horizontal piping type and left side high pressure
Amplifier housing 1 Cast aluminum alloy
Electrical connection 9 M20 female, two electrical connections with a blind plug(1)
Integral indicator D Digital indicator(2)
Mounting bracket N None
Process connection style -W Flush type
Flange rating A4 ANSI class 600
Process connection size (Process flange size) 3 3-inch (80 mm)
Flange material C 316 SST(3)
Gasket contact surface(4) 1 Serration (for ANSI flange with wetted parts material SW only)
Wetted parts material(5) SW Diaphragm: 316L SST
Others: 316L SST
Flushing connection ring(6) *0 Ring: None
Vent/Drain plugs: -
Material: -
Extension 0 None
Fill fluid(7) -C For high temperature use (silicone oil)(8)(9)
Process temperature: 10 to 310??C
Ambient temperature: 10 to 60??C
Capillary connection A Side of diaphragm seal unit
2 Always 2
Capillary length(10) 5 5 m

/KF25
Material certificate /M2W Process flange, Block
For Flush type
Pressure test/ Leak test certificate(11)(12) /T58 ANSI/JPI Class 600(13)
16 MPa (2300 psi)

Nitrogen Gas(14)
Retention time: one minute 

The ??*?? marks indicate the most typical selection for each specification
  1. Material of a blind plug; aluminum alloy for code 5 and 9, and SUS304 for code 7.
  2. Not applicable for output signal code G.
  3. Forged version of the material may be used.
  4. See table 3 ??Gasket contact surface?? on page 6.
  5. Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user??s process fluids.
    Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and hightemperature steam (150??C [302??F] or above). Contact Yokogawa for detailed information of the wetted parts material.
  6. When specified flushing connection ring code 1 or 2, exclusive gaskets are provided for transmitter side.
  7. Even in case where fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing and dehydrating treatment for the wetted parts is required, specify option code K1 or K5.
  8. Wetted parts material code TW (Tantalum) cannot be applied.
  9. Not applicable for flashing connection ring code 1 and 2.
  10. In case of wetted parts material code HW (Hastelloy C) and TW (Tantalum) for 2-inch process flange, specify capillary length from 1 to 5m.
  11. The unit on the certificate is always MPa regardless of selection of option code D1, D3, or D4.
  12. A flushing connection ring will not be applied when conducting the pressure test or leak test.
  13. Applicable for flush type (process connection style code W.)
  14. Dry nitrogen gas is used for oil-prohibited use (option code K1 and K5.)

NOTE:
This item is a replacement of EJA118W-FHSA4EB-CA05-99DN/KF25/M05/T39


  • Estimated Lead Time: 10 - 12
  • Shipping Weight: 20 Kg

Add to Cart:

  • Model: EJA118E-FHSCG-919DN-WA43C1SW00-CA25/KF25/M2W/T58
  • 7 Units in Stock


Processing Time
  • Ships in 24 hours: Processing Time is guaranteed to be shorter than 24 hours.
  • Typical Processing Time: 3 - 12 days

We ship to over 200 countries worldwide!