Part Number: YTA110-EA4DB/KU2
Model and Suffix Codes
Model: YTA110 - Temperature Transmitter
Output Signal: -E - 4 to 20mA DC with digital communication (HART protocol, refer to GS 01C50T01-00EN)
A - Always A
Electrical Connection: 4 - M20 female
Integral Indicator: D - with digital indicator
Mounting Bracket: B - SUS304 Stainless steel 2-inch vertical pipe mounting?
Option Codes: /KU2 -
ATEX
ATEX Intrinsically safe ia, Flameproof approval and Intrinsically safe ic combination
[Intrinsically safe ia approval]
Applicable standard: EN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007
Certificate: KEMA 02ATEX1026 X
II 1 G Ex ia IIC T4...T5 Ga Ambient Temerature: -40 to 70?C for T4, -40 to 50?C for T5
Enclosure: IP66/IP67
Supply/Output circuit: Ui=30V, Ii=165mA, Pi=900mW, Ci=20nF, Li=730?H
Input circuit: Uo=9V, Io=40mA, Po=90mW, Co=0.7?F, Lo=10mH
Electrical Connection: 1/2 NPT female and M20 female?
[Flameproof and Dust Ignition Proof Approval]
Applicable Standard: EN 60079-0: 2012+A11: 2013, EN 60079-1: 2007, EN 60079-31:2009
Certificate: KEMA 07ATEX0130
II 2 G Ex d IIC T6/T5 Gb, II 2 D Ex tb IIIC T70?C, T90?C Db
Ambient Temperature for Gas Atmospheres: -40 to 75?C for T6, -40 to 80?C for T5
Ambient Temperature for Dust Atmospheres: -30 to 65?C for T70?C, -30 to 80?C for T90?C
Enclosure: IP66/IP67
Electrical Connection: 1/2 NPT female and M20 female?
[Intrinsically safe ic]
Applicable standard: EN 60079-0:2012, EN 60079-11:2012
II 3 G Ex ic IIC T5...T4 Gc Ambient Temperature: -30 to 70?C for T4, -30 to 50?C for T5
Enclosure: IP66/IP67
Supply/Output circuit: Ui=30V, Ci=28nF, Li=730?H
Input circuit: Uo=9V, Io=40mA, Po=90mW, Co=0.7?F, Lo=10mH
Electrical connection: 1/2 NPT female and M20 female?
NOTE:
(1) For flat-panel mounting, please prepare bolts and nuts.
- Estimated Lead Time: 10 - 12