EJX530A-EBS4N-019DN/KS21/D3/X2/T06/M15 New Yokogawa EJX530A Gauge Pressure Transmitter

EJX530A-EBS4N-019DN/KS21/D3/X2/T06/M15 New Yokogawa EJX530A Gauge Pressure Transmitter

$2,463.00  $1,207.00
Save: 51% off


Part Number: EJX530A-EBS4N-019DN/KS21/D3/X2/T06/M15
Model: EJX530A Gauge Pressure Transmitter
Brand: Yokogawa
Condition: New & Original in Factory Packing
Factory Warranty: 12 Months

Overview
The EJX-A series is Yokogawa's premium performance line of DPharp transmitters. Released in 2004, it offers the performance and stability needed in demanding applications. The EJX-A series performance makes it the thoroughbred of the DPharp family of pressure transmitters.

The EJX530A is an In-Line Gauge Pressure Transmitter in the series.

EJX530A standard features include:
  • ??0.04% Accuracy
  • ??0.1% per 15 years Stability
  • 90 ms Response Time
  • Exida and TUV SIL 2/3 Certified
  • Local Parameter Setting (LPS)

Specifications
  • Measurement Types
    Primary Variable:
    Absolute Pressure
  • Reference Accuracy
    Primary Variable:
    ??0.04% of Span
  • Stability
    Primary Variable:
    ??0.1% of URL per 10 years
  • Response Time
    Primary Variable:
    90ms
  • Rangeability
    Primary Variable:

    A Capsule: 25:1
    B, C, or D Capsule: 50:1
  • Burst Pressure (Absolute)
    A, B, or C Capsule:
    4,350 psi (30 MPa)
    D Capsule: 19,100 psi (132 MPa)
  • Specification Conformance
    EJX-A Series:
    ??3s

Model and Suffix Codes

Model EJX530A Gauge pressure transmitter
Output signal -E 4 to 20 mA DC Output with digital communication (HART 5 protocol)
Measurement span (capsule) B 0.04 to 2 MPa (5.8 to 290 psi)
Wetted parts material(1) S Process connector: 316L SST#
Diaphragm: Hastelloy C-276(2)#
Others: 316L SST#
Process connections 4 1/2 NPT female
N Always N
-0 Always 0
Amplifier housing *1 Cast aluminum alloy
Electrical connection 9 M20 female, two electrical connections with a blind plug(3)
Integral indicator D Digital indicator(4)
Mounting bracket N None
ATEX /KS21 ATEX Intrinsically safe Approval(5)(6)
Applicable Standard: EN IEC 60079-0, EN 60079-11
Certificate: DEKRA 11ATEX0228 X
II 1 G Ex ia IIC T4 Ga, II 2 D Ex ia IIIC T85??C T100??C T120??C Db
Degree of protection: IP66/IP67
Amb. Temp. (Tamb) for EPL Ga: ?C50 to 60??C (?C58 to 140??F)
Maximum Process Temp. (Tp) for EPL Ga:120??C
Electrical data: Ui=30 V, Ii=200 mA, Pi=0.9 W, Ci=27.6 nF, Li=0 ??H
Amb. Temp. for EPL Db: ?C30 to 60??C(7)
Max. surface Temp. for EPL Db: T85??C (Tp: 80??C), T100??C (Tp: 100??C), T120??C (Tp: 120??C)
Calibration units(8) /D3 bar calibration (bar unit)
Painting /X2 Coating change: Anti-corrosion coating(9)
Pressure test/ Leak test certificate(10)(11) /T06 Test Pressure: 2 MPa (290 psi)(12)
Material certificate(11)(13) /M12 Process Connector

The ??*?? marks indicates the most typical selection for each specification.
  1. Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user??s process fluids.
    Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150??C [302??F] or above). Contact Yokogawa for detailed information of the wetted parts material.
  2. Hastelloy C-276 or ASTM N10276.
  3. Material of a blind plug; aluminum alloy for code 5 and 9, and SUS304 for code 7.
  4. Not applicable for output signal code G.
  5. Applicable for Electrical connection code 2, 4, 7, 9, C and D.
  6. Not applicable for option code /AL.
  7. Lower limit of temperature is ?C15??C (5??F) when /HE is specified.
  8. The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by option codes D1, D3, and D4.
  9. Not applicable with color change option. Not applicable for amplifier housing code 2.
  10. The unit on the certificate is always kPa/MPa regardless of selection of option code D1, D3 and D4.
  11. Not applicable with process connections code for diaphragm seal system P.
  12. Applicable for capsule code B.
  13. Material traceability certification, per EN 10204 3.1 B.

The ??#??marks indicate the construction materials conform to NACE material recommendations per MR0175/ISO 15156. Please refer to the latest standards for details. Selected materials also conform to NACE MR0103.


  • Estimated Lead Time: 13 - 18
  • Shipping Weight: 3 Kg

Add to Cart:

  • Model: EJX530A-EBS4N-019DN/KS21/D3/X2/T06/M15
  • 7 Units in Stock


Processing Time
  • Ships in 24 hours: Processing Time is guaranteed to be shorter than 24 hours.
  • Typical Processing Time: 3 - 12 days

We ship to over 200 countries worldwide!