Product Number: EJA530E-JDS7N-024DL/KS21

Ordering Information
  • Model: EJA530E - Gauge pressure transmitter
  • Output Signal: -J - 4 to 20 mA DC Output with digital communication (HART 5/ HART 7 protocol)?
  • Measurement span (capsule): D5 to 50 MPa (720 to 7200 psi)9
  • Wetted parts material?: S -
    [
    Process connector316L SST#
    [DiaphragmHastelloy C-276?#
    [Others
    316L SST#
  • Process connections: 7 - 1/2 NPT male
  • N: Always N
  • -0: Always 0
  • Amplifier housing: 2ASTM CF-8M stainless steel4
  • Electrical connection: 4 - M20 female, two electrical connections without blind plugs
  • Integral indicator: D - Digital indicator5
  • Mounting bracket: L316 SST 2-inch pipe mounting
  • Optional Codes: KS21 - ATEX
    ATEX Intrinsically safe Approval6,7
    Applicable Standard: EN 60079-0:2012/A11:2013, EN 60079-11:2012, EN 60079-26:2007
    Certificate: DEKRA 11ATEX0228 X
    II 1G, 2D Ex ia IIC T4 Ga, Ex ia IIIC T85?C T100?C T120?C Db
    Degree of protection: IP66/IP67
    Amb. Temp. (Tamb) for EPL Ga: ? to 60?C (? to 140?F) 
    Maximum Process Temp. (Tp) for EPL Ga:120?C
    Electrical data: Ui=30 V, Ii=200 mA, Pi=0.9 W, Ci=27.6 nF, Li=0 ?H
    Amb. Temp. for EPL Db: ? to 60?C 8
    Max. surface Temp. for EPL Db: T85?C (Tp: 80?C), T100?C (Tp: 100?C), T120?C (Tp: 120?C)
     

  1. HART 5 or HART 7 is selectable. Specify upon ordering.
  2. Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user s process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150?C [302?F] or above). Contact Yokogawa for detailed information of the wetted parts material.
  3. Hastelloy C-276 or ASTM N10276.
  4. Not applicable for electrical connection code 0, 5, 7 or 9.
  5. Not applicable for output signal code G.
  6. Applicable for Electrical connection code 2, 4, 7, 9, C and D
  7. Not applicable for output signal code Q.
  8. Lower limit of ambient temperature is ??C (5?F) when /HE is specified.
  9. 5 to 70 MPa (720 to 10150 psi) when /HG is specified.

  • Estimated Lead Time: 8 - 10