shoping-cartYour cart is empty
    Sign In or Register



    Sign In Socially

    If you are a member of facebook or google or yahoo, you can login to our system by clicking on the icon below.


EJA118E-FMSCC-919DN-WJ22B1SW00-BA22/KF22 New Yokogawa EJA118E Diaphragm Sealed Differential Pressure Transmitter

EJA118E-FMSCC-919DN-WJ22B1SW00-BA22/KF22 New Yokogawa EJA118E Diaphragm Sealed Differential Pressure Transmitter

$4,505.00  $2,208.00
Save: 51% off


Part Number: EJA118E-FMSCC-919DN-WJ22B1SW00-BA22/KF22
Model: EJA118E Diaphragm Sealed Differential Pressure Transmitter
Manufacturer: Yokogawa
Condition: New & Original in Factory Packing
Factory Warranty: 12 Months

Description
The EJA-E series of transmitters is Yokogawa's most recent evolution of the DPharp family. Released in 2012, it combines the ruggedness and success of the work-horse EJA-E series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa.

The EJA118E is a Differential Pressure Transmitter with remote diaphragm seals.

EJA118E features include:
  • ??0.2% Accuracy
  • 200 ms Response Time
  • Exida and TUV SIL2 / SIL3 Certified
  • Local Parameter Setting (LPS)
  • 10-segment Signal Characterizer
  • Active Capillary Fill Fluid Density Compensation

Model and Suffix Codes

Model EJA118E Diaphragm sealed differential pressure transmitter
Output signal -F Digital communication (FOUNDATION Fieldbus protocol, refer to GS 01C31T02-01EN)
Measurement span (capsule) M 2.5 to 100 kPa (10 to 400 inH2O)
S Always S
C Always C
Cover flange bolts and nuts material C 660 SST
Installation -9 Horizontal piping type and left side high pressure
Amplifier housing 1 Cast aluminum alloy
Electrical connection 9 M20 female, two electrical connections with a blind plug(1)
Integral indicator D Digital indicator(2)
Mounting bracket N None
Process connection style -W Flush type
Flange rating J2 JIS 20K
Process connection size (Process flange size) 2 2-inch (50 mm)
Flange material B 304 SST(3)
Gasket contact surface(4) 1 Serration (for ANSI flange with wetted parts material SW only)
Wetted parts material(5) SW Diaphragm: 316L SST
Others: 316L SST
Flushing connection ring(6) *0 Ring: None
Vent/Drain plugs: -
Material: -
Extension 0 None
Fill fluid(7) -B For general use (silicone oil)
Process temperature: ?C30 to 180??C
Ambient temperature: ?C15 to 60??C
Capillary connection A Side of diaphragm seal unit
2 Always 2
Capillary length(8) 2 2 m
ATEX /KF22 ATEX Flameproof Approval(9)(10)
   Applicable Standard: EN IEC 60079-0, EN 60079-1, EN 60079-31
   Certificate: KEMA 07ATEX0109 X
   II 2G, 2D Ex db IIC T6...T4 Gb, Ex tb IIIC T85??C Db
   Degree of protection: IP66/IP67
   Amb. Temp. (Tamb) for gas-proof:
   T4; ?C50 to 75??C (?C58 to 167??F), T5; ?C50 to 80??C (?C58 to 176??F), T6; ?C50 to 75??C (?C58 to 167??F)
   Process Temp. for gas-proof (Tp):
   T4; ?C50 to 120??C (?C58 to 248??F), T5; ?C50 to 100??C (?C58 to 212??F), T6; ?C50 to 85??C (?C58 to 185??F)
   Max. surface Temp. for dust-proof: T85??C (Tamb: ?C30 to 75??C, Tp: ?C30 to 85??C)(11)

The ??*?? marks indicate the most typical selection for each specification
  1. Material of a blind plug; aluminum alloy for code 5 and 9, and SUS304 for code 7.
  2. Not applicable for output signal code G.
  3. Forged version of the material may be used.
  4. See table 3 ??Gasket contact surface?? on page 6.
  5. Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user??s process fluids.
    Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and hightemperature steam (150??C [302??F] or above). Contact Yokogawa for detailed information of the wetted parts material.
  6. When specified flushing connection ring code 1 or 2, exclusive gaskets are provided for transmitter side.
  7. Even in case where fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing and dehydrating treatment for the wetted parts is required, specify option code K1 or K5.
  8. In case of wetted parts material code HW (Hastelloy C) and TW (Tantalum) for 2-inch process flange, specify capillary length from 1 to 5m.
  9. Applicable for Electrical connection code 2, 4, 7, 9, C and D.
  10. Not applicable for output signal code Q.
  11. Lower limit of ambient temperature is ?C15??C (5??F) when /HE is specified.


NOTE:
This item is a replacement of EJA118W-FMSJ2BB-AA02-99DN/KF21


  • Estimated Lead Time: 10 - 12
  • Shipping Weight: 16 Kg

Add to Cart:

  • Model: EJA118E-FMSCC-919DN-WJ22B1SW00-BA22/KF22
  • 7 Units in Stock


Processing Time
  • Ships in 24 hours: Processing Time is guaranteed to be shorter than 24 hours.
  • Typical Processing Time: 3 - 12 days

We ship to over 200 countries worldwide!