Part Number: 3144PD6A1K7B5M5CNQ4QTModel: 3144P Temperature Transmitter
Manufacturer: Rosemount
Condition: New & Original in Factory Packing
Factory Warranty: 12 Months
Specifications
- Input: Dual and single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms)
- Output Signal: 4-20 mA /HART® protocol, FOUNDATION? Fieldbus protocol
- Housing: Dual-compartment field mount
- Display/Interface: Large LCD display with percent range graph and buttons/switches
- Diagnostics: Basic diagnostics, Hot Backup? capability, sensor drift alert, thermocouple degradation, min/max tracking
- Calibration Options: Transmitter-sensor matching (Callendar-Van Dusen constants), custom trim
- Certifications/Approvals: SIL 2/3 certified to IEC 61508 by an independent 3rd party, hazardous location, marine type, see full specs for complete list of certifications
Features
- Industry-leading accuracy and reliability for best performance in critical control and safety applications.
- Transmitter-sensor matching improves measurement accuracy up to 75%.
- 5-year long-term stability extends calibration intervals to reduce trips to the field.
- Rosemount X-well Technology measures temperature without a process penetration for reduced design, installation and maintenance costs.
Ordering Information
Model |
3144P |
Temperature transmitter |
Housing style |
D6 |
Field mount housing, dual-compartment housing Material: Stainless steel Conduit entry size: M20 1,5 (CM20) |
Transmitter output |
A |
4??20 mA with digital signal based on HART Protocol |
Measurement configuration |
1 |
Single-sensor input |
Product Certificates |
K7(1)(2) |
IECEx Intrinsic Safety, Flameproof, Dust Ignition-Proof and Type n combination |
Mounting bracket |
B5 |
??L?? mounting bracket for 2-in. pipe or panel mounting - All SST |
Display |
M5 |
LCD display |
Alarm level configuration |
CN |
NAMUR alarm and saturation levels, low alarm |
Calibration certification |
Q4 |
Calibration certificate (3-point calibration) |
Quality certification for safety |
QT |
Safety-certified to IEC 61508 with certificate of FMEDA data (HART only) |
- When IS approval is ordered on a FOUNDATION Fieldbus, both standard IS and FISCO IS approvals apply. The device label is marked appropriately.
- Consult factory for availability when ordering with HART or FOUNDATION Fieldbus models.
- Estimated Lead Time: 4 - 6
- Shipping Weight: 8 Kg