2088G4S22A2B4I1C4S5Q4D4HR5 New Rosemount 2088 Gage Pressure Transmitter

2088G4S22A2B4I1C4S5Q4D4HR5 New Rosemount 2088 Gage Pressure Transmitter

$1,041.00  $657.00
Save: 37% off


Part Number: 2088G4S22A2B4I1C4S5Q4D4HR5
Manifold Model: 0306RT22BA11
Model: 2088 Gage Pressure Transmitter
Manufacturer: Rosemount

Ordering Information
  • Model: 2088 - Pressure Transmitter
  • Measurement type: G - Gage
  • Pressure ranges: 4 -14.7 to 4,000 psi (-1,01 to 275,8 bar)
  • Transmitter output1: S4?20 mA dc/Digital HART Protocol
  • Materials of construction2: 22
    Process connection: 
    316L SST
    Isolating diaphragm: 316L SST
    Fill fluid: Silicone
  • Process connection: A1/2?14 NPT female
  • Conduit entry: 23 - M20 x 1.5
  • Mounting brackets: B4 - SST mounting bracket with SST bolts
  • Product certifications: I13 - ATEX Intrinsic Safety
  • Digital signal: C43NAMUR alarm and saturation levels, high alarm
  • Manifold assemblies4,5: S5 - Assemble to Rosemount 306 Integral Manifold
  • Calibration certificate: Q4 - Calibration certificate
  • Configuration buttons: D4 - Analog zero and span
  • HART Revision configuration6: HR57 - Configured for HART Revision 5

  1. HART Revision 5 is the default HART output. The Rosemount2088 with selectable HART can be factory or field configured to HART Revision 7. To order HART Revision 7 factory configured, add option code HR7.
  2. Materials of construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
  3. Not available with Low Power transmitter output code N.
  4. Use 1/2?14 NPT female process connection code A.
  5. ?Assemble-to? items are specified separately and require a completed model number.
  6. Select configuration buttons (option code D4 or DZ) or local operator interface (option code M4) if local configuration buttons are required.
  7. Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.