Part Number: 1756-PA75
Model: ControlLogix Standard Power Supply
Manufacturer: Allen Bradley
Condition: New & Original in Factory Packing
Factory Warranty: 12 Months

Technical Specifications
  • Input voltage range1: 85...265V AC
  • Input voltage, nom: 120V/240V AC
  • Input frequency range: 47...63 Hz
  • Input power, max: 100VA/100 W
  • Output power, max: 75 W @ 0...60??C (32...140??)2
  • Power consumption: 25 W @ 0...60??C (32...140??)
  • Power dissipation: 85.3 BTU/hr
  • Hold-up time3:
    5 cycles @ 85V AC, 50/60 Hz
    6 cycles @ 120V AC, 50/60 Hz
    6 cycles @ 200V AC, 50/60 Hz
    6 cycles @ 240V AC, 50/60 Hz
  • Inrush current, max: 20 A
  • Current capacity at 1.2V DC: 1.5 A
  • Current capacity at 3.3V DC: 4 A
  • Current capacity at 5.1V DC: 13 A
  • Current capacity at 24V DC: 2.8 A
  • Overcurrent protection, max: User-supplied 15 A4
  • Fusing: Non-replaceable fuse is soldered in place5
  • Transformer load, max: 100VA
  • Isolation voltage:
    250V (continuous), reinforced insulation type
    Type tested @ 3500V DC for 60 s, power input-to-backplane approx
  • Module location: Left side of 1756 chassis
  • Chassis compatibility: Series B
  • Wire size: 2.5 mm2 (14 AWG) solid or stranded copper wire rated at 90?C (194?F), or greater, 1.2 mm (3/64 in.) insulation max
  • Wire category: 1-on power ports6
  • Conductor screw torque: 0.8 N m (7 lb in)
  • North American temperature code: T4
  • Enclosure type rating: None (open-style)

NOTE:
  1. UL certification for 120/240V AC, 50/60 Hz nominal. Rockwell Automation specified 85 265V AC, 47 63 Hz.
  2. The combination of all output power (5.1V backplane, 24V backplane, 3.3V backplane, and 1.2V backplane) cannot exceed 75 W.
  3. The hold-up time is the time between input voltage removal and DC power failure.
  4. Use time-delay type overcurrent protection in all ungrounded conductors.
  5. This fuse is intended to guard against fire hazard due to short circuit conditions.
  6. Use this conductor category information for planning conductor routing as described in the system level installation manual.


  • Availability: In Stock
  • Estimated Lead Time: Usually Ships in 1 - 7 Working Days
  • Shipping Weight: 3 Kg

Add to Cart:

  • Model: 1756-PA75
  • 7 Units in Stock


Processing Time
  • Ships in 24 hours: Processing Time is guaranteed to be shorter than 24 hours.
  • Typical Processing Time: 3 - 12 days

We ship to over 200 countries worldwide!

You May Also Like

6MF2832-0AA00 New Siemens Analog Input Module
$769.00  $377.00
Save: 51% off
TSXP575634M New Modicon Unity Processor
$12,226.00  $5,991.00
Save: 51% off
FX3U-16MR-DS New Mitsubishi FX3U Main Unit
$570.00  $279.00
Save: 51% off
3BHB006208R0001 New ABB UNS 0883A-P,V1
$7,162.00  $4,262.00
Save: 40% off
CC-TDI110 New Honeywell Digital Input Module
$6,667.00  $3,267.00
Save: 51% off