1756-OW16I/A New Allen Bradley Contact Output Module

1756-OW16I/A New Allen Bradley Contact Output Module

$503.00  $299.00
Save: 41% off


Part Number: 1756-OW16I/A
Model: Contact Output Module
Manufacturer: Allen Bradley
Condition: New & Original in Factory Packing
Factory Warranty: 12 Months

Technical Specifications
  • Outputs: 16 N.O. individually isolated
  • Pilot duty: C300/R150
  • Operating voltage range:
    5...125V DC
    10...240V AC
  • Output voltage range (load dependent):
    1 A @ 5 30V DC
    0.5 A @ 48V DC
    0.22 A @ 125V DC
    1.5A @ 120V AC 50/60 Hz
    0.75A @ 240V AC 50/60 Hz
  • Output delay time:
    Off to On: 10 ms max
    On to Off: 10 ms max
  • Current draw @ 5.1V: 150 mA
  • Current draw @ 24V: 150 mA
  • Total backplane power: 4.4 W
  • Power dissipation, max: 4.5 W @ 60??C (140??F)
  • Thermal dissipation: 15.35 BTU/hr
  • Off-state leakage current per point, max: 1.5 mA per point
  • On-state voltage drop, max: 400 mV DC @ 1 A
  • Minimum load current: 10 mA per point
  • Current per module, max: 8 A @ 60??C (140??F)
  • Initial contact resistance, max: 100 m @ 6V 1 A
  • Switching frequency, max: 1 operation/3 s (0.3 Hz at rated load)
  • Bounce time, mean: 1.2 ms
  • Expected contact life:
    300 K cycles resistive
    100 K cycles inductive
  • Scheduled outputs: Synchronization within 16.7 s max, reference to the Coordinated System Time
  • States in Fault mode per point: Hold last state, On or Off (Off is default)
  • States in Program mode per point: Hold last state, On or Off (Off is default)
  • Isolation voltage: 
    250V (continuous), basic insulation type, outputs-to-backplane, and output-to-output
    Routine tested @ 1350V AC for 2 s
  • Module keying: Electronic, software configurable
  • Fusing: Not protected. A fused IFM can be used to protect outputs.
  • RTB keying: User-defined mechanical
  • Slot width: 1
  • Wire category: 11
  • North American temperature code: T4
  • Enclosure type: None (open-style)

  1. Use this conductor category information for planning conductor routing as described in the system-level installation manual. See the Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1


  • Availability: In Stock
  • Estimated Lead Time: Usually Ships in 7 - 10 Working Days
  • Shipping Weight: 3 Kg