shoping-cartYour cart is empty
    Sign In or Register



    Sign In Socially

    If you are a member of facebook or google or yahoo, you can login to our system by clicking on the icon below.


YTA710-JA1A2DB/KU2/C3/N4 New Yokogawa YTA710 Temperature Transmitter

YTA710-JA1A2DB/KU2/C3/N4 New Yokogawa YTA710 Temperature Transmitter

$1,348.00  $661.00
Save: 51% off


Part Number: YTA710-JA1A2DB/KU2/C3/N4
Model: YTA710 Temperature Transmitter
Brand: Yokogawa
Condition: New & Original in Factory Packing
Factory Warranty: 12 Months

Overview
The YTA710 provides high accuracy, stability, and reliability. The housing structure adopts reliable dual-compartment structure. The sensor input can be choice of single or dual inputs. This input can accept the RTD, thermocouple, ohm, or DC millivolt. It converts the sensor input to a 4 to 20mA DC analog signal or Fieldbus digital signal. HART 7 Protocol, BRAIN Protocol or FOUNDATION? Fieldbus ITK 6 version are available. The dual input can accept two sensors calculation of the differential or average value and the sensor backup function. Sensor backup functions for automatically switches-over from the primary to the backup upon sensor failure.

By adoption of local parameter switch on the Indicator, it becomes easy to do the on-site setting work.

YTA710 features include:
  • Dual-compartment field-mount housing
  • Choice of HART 7, BRAIN Protocol or FOUNDATION Fieldbus ITK 6 Protocol
  • Local Parameter Setting function (Indicator model)
  • Advanced diagnosis

Ordering Information

Model YTA710 Temperature Transmitter
Output signal -J 4 to 20 mA DC with digital communication HART protocol
A Always A (Global)
Sensor input 1 Single
Housing code A Aluminum
Electrical connection 2 1/2 NPT female
Integral indicator D Digital indicator with Local Operating Switch
Mounting bracket B 304 SST or ASTM304L stainless steel 2-inch horizontal pipe mounting bracket(1)
ATEX /KU2 4-20mA:
[Intrinsically safe ia approval]
     Applicable Standard: EN IEC 60079-0, EN 60079-11
     Certificate No. FM16ATEX0019X
     II 1 G Ex ia IIC T5??T4 Ga
     II 2 (1) D Ex ia [ia Da] IIIC T135??C Db
     Ambient Temperature: ?C40 to +70??C for T4, ?C40 to +50??C for T5, ?C30 to +70??C for IIIC
     Enclosure: IP66/IP67
     Electrical parameters:
          Supply/Output circuit: Terminals: +, ?C
          Ui=30V, Ii=200mA, Pi=1.0W, Ci=22nF, Li=0mH
          Sensor circuit: Terminals: 1, 2, 3, 4, 5
          Uo=6V, Io=90mA, Po=135mW, Co=10??F, Lo=3.9mH Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)
[Intrinsically safe ic]
      Applicable Standard: EN IEC 60079-0, EN 60079-11
      Certificate: Not Applicable as per Annex VIII to ATEX 2014/34/EU
      II 3 G Ex ic IIC T5...T4 Gc
      Ambient Temperature: ?C30 to +70??C for T4, ?C30 to +50??C for T5
      Enclosure: IP66/IP67
      Overvoltage category: I
      Electrical parameters:
           Supply/Output circuit: Terminals: +, ?C
           Ui=30V, Ci=2.2nF, Li=0mH
           Sensor circuit: Terminals: 1, 2, 3, 4, 5
           Uo=6V, Io=90mA, Po=135mW, Co=10??F, Lo=3.9mH
      Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)
[Flameproof and Dust Ignition Proof Approval]
     Same as KF2
NAMUR NE43 compliant(2) /C3 Output signal limits: 3.8 mA to 20.5 mA

Failure alarm up-scale: output status at CPU failure and hardware error is 110%, 21.6 mA or more.
In this case Sensor burnout is High: 110%, 21.6 mA DC.
Wired tag plate /N4 SUS316 stainless steel tag plate wired onto transmitter

  1. For flat-panel mounting, please prepare bolts and nuts.
  2. Not applicable for Fieldbus type.


  • Estimated Lead Time: 8 - 10
  • Shipping Weight: 8 Kg

Add to Cart:

  • Model: YTA710-JA1A2DB/KU2/C3/N4
  • 7 Units in Stock


Processing Time
  • Ships in 24 hours: Processing Time is guaranteed to be shorter than 24 hours.
  • Typical Processing Time: 3 - 12 days

We ship to over 200 countries worldwide!