shoping-cartYour cart is empty
    Sign In or Register



    Sign In Socially

    If you are a member of facebook or google or yahoo, you can login to our system by clicking on the icon below.


YTA610-JA1A4DN/KU2/C2 New Yokogawa YTA610 Temperature Transmitter

YTA610-JA1A4DN/KU2/C2 New Yokogawa YTA610 Temperature Transmitter

$1,107.00  $543.00
Save: 51% off


Part Number: YTA610-JA1A4DN/KU2/C2
Model: YTA610 Temperature Transmitter
Brand: Yokogawa
Condition: New & Original in Factory Packing
Factory Warranty: 12 Months

Model and Suffix Codes

Model YTA610 YTA610 Temperature Transmitter
Output signal -J 4 t0 20 mA DC with digital communication HART 7 protocol
A Always A
Sensor input 1 Single
Housing code A Aluminum
Electrical connection 4 M20 female
Integral indicator D Digital indicator with Local Operating Switch
Mounting bracket N None
ATEX /KU2 4-20mA:
[Intrinsically safe approval]
Applicable Standard: EN 60079-0: 2012+A11:2013, EN 60079-11: 2012
Certificate No. FM16ATEX0019X
II 1 G Ex ia IIC T5...T4 Ga
II 2 (1) D Ex ia [ia Da] IIIC T135??C Db
Ambient Temperature: ?C40 to +70??C for T4, ?C40 to +50??C for T5, ?C30 to +70??C for IIIC
Enclosure: IP66/IP67
Electrical parameters:
Supply/Output circuit: Terminals: +, ?C
Ui=30V, Ii=200mA, Pi=1.0W, Ci=22nF, Li=0mH
Sensor circuit: Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10??F, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)

[Intrinsically safe ic]
Applicable Standard: EN IEC 60079-0, EN 60079-11
Certificate: Not Applicable as per Annex VIII to ATEX 2014/34/EU
II 3 G Ex ic IIC T5...T4 Gc
Ambient Temperature: ?C30 to +70??C for T4, ?C30 to +50??C for T5
Enclosure: IP66/IP67
Overvoltage category: I
Electrical parameters:
Supply/Output circuit: Terminals: +, ?C
Ui=30V, Ci=22nF, Li=0mH
Sensor circuit: Terminals: 1, 2, 3, 4, 5
Uo=6V, Io=90mA, Po=135mW, Co=10??F, Lo=3.9mH
Dielectric strength: 500 V a.c.r.m.s.,1 min (Without /A)

[Flameproof and Dust Ignition Proof Approval]
Applicable Standard: EN IEC 60079-0, EN 60079-1, EN 60079-31
Certificate: KEMA 07ATEX0130X
II 2 G Ex db IIC T6/T5 Gb, II 2 D Ex tb IIIC T70??C/T90??C Db
Ambient Temperature for Gas Atmospheres: ?C40 to 75??C for T6, ?C40 to 80??C for T5
Ambient Temperature for Dust Atmospheres: ?C30 to 65??C for T70??C, ?C30 to 80??C for T90??C
Enclosure: IP66/IP67
Electrical Connection: 1/2 NPT female and M20 female(1)
NAMUR NE43 compliant(2) /C2 Output signal limits: 3.8 mA to 20.5 mA
Failure alarm down-scale: output status at CPU failure and hardware error is ?C5%, 3.2 mA or less.
Sensor burnout is also set to Low: ?C2.5%, 3.6 mA DC.

  1. Applicable for Electrical Connection Code 2 and 4.
  2. Not applicable for Fieldbus type.


  • Estimated Lead Time: 6 - 8
  • Shipping Weight: 5 Kg

Add to Cart:

  • Model: YTA610-JA1A4DN/KU2/C2
  • 7 Units in Stock


Processing Time
  • Ships in 24 hours: Processing Time is guaranteed to be shorter than 24 hours.
  • Typical Processing Time: 3 - 12 days

We ship to over 200 countries worldwide!