Product Number: ST5484E-151-132-XX-M1376Model: Seismic Velocity Transmitter
Brand: Metrix
Ordering Information
- Model: ST5484E - Seismic Velocity 4-20 mA Velocity Transmitter
- Full Scale Range1: 151 - 1.0 in/sec (25.4 mm/s) true RMS
- Housing Material & Stud Size1: 1 - 303 SS housing, ??? NPT stud
- Hazardous Area Certification2,3,4: 3 - ATEX, EEx ia IIC T4 Ga (intrinsically safe)
- Connection Type2: 2 - Terminal Block, 2-wire6 ; (4-20 mA output only)
- High-Pass Filter: X - Custom (consult factory)5
- Low-Pass Filter: X - Custom (consult factory)5
- M1370
NOTES:
- The ST5484E uses an RMS amplitude detection circuit. Full scale ranges in peak units use scaled RMS (i.e., RMS x v2). The ??derived peak?? measurements will equal true peak only under the special case of a pure sinusoid, not complex vibration signals.
- Hazardous Area Certifications are not compatible with all connection types. Consult Table 3 for allowable combinations of C & D options.
- Some approvals require intrinsic safety barriers, others require Explosion-Proof wiring practices.
- ATEX/IECEx/INMETRO Ex d (flameproof) approvals (ordering option C=8 or C=6) require conduit elbow 8200-AAA-IEC, sold separately.
- High- and Low-Pass filter corners for standard filters must be separated by at least one octave (low-pass frequency must be at least twice the high-pass frequency). All combinations are allowed except E = 6 and F = 4, 5, or 6. Custom filters with closer separation and/or different roll-offs may be available in some instances. Consult the factory if custom filters are required.
- Estimated Lead Time: 3 - 5
- Shipping Weight: 2 Kg