Description
The short-tube Rotameter is used for measurement of flow rates of liquids and gases. Its special application is in turbulent, opaque or aggressive fluids. The instrument is mounted in a vertical pipeline with flow direction upwards. Inside the special shaped conical metal tube, a float is guided concentrically. The position of this float is magnetically transmitted to the indicator. The indicators are exchangeable without influencing the accuracy.

Features
  • Different process connections like flanges according to EN and ASME
  • All wetted parts in stainless steel or PTFE
  • Flow range water: 0.0025 to 130 m³/h
  • Flow range air: 0.075 to 1400 m³/h (+20 °C, 1.013 bar abs)
  • Measuring accuracy acc. standard VDI/VDE 3513 sheet 2 (qG = 50 %) at calibration conditions
  • Float damping to avoid float bouncing with gas applications
  • Optional heat tracing (with steam or fluid heat carrier)
  • Indicator in steel or aluminum, protection class IP66/67
  • Mechanical indicator without additional power supply
  • Microprocessor controlled transmitter with 24 V, 115 V or 230 V power supply
  • Intrinsically safe version (Ex i): ATEX, IECEx, FM (C/US), NEPSI, PESO, EAC
  • Flame proof version (Ex d): ATEX, IECEx, NEPSI, PESO, KOSHA, EAC, TS
  • Dust explosion proof: ATEX, IECEx, NEPSI, TS
  • Ex for non-electrical RAMC: ATEX, EAC
  • FMEDA report available for SIL application
  • Limit switches, also available as “fail-safe???version
  • Electronic transmitter as standard with digital display with the following features:
    - Flow indication (totalizer, actual, percent)
    - Indication of different volume- and mass flow units
    - Possibility of user calibration in the field
    - Float blocking indication function
    - Adjustable signal output damping
    - Error message indication
    - Temperature measurement in the electronic transmitter
    - HART® 5/7-Communication

NOTE: Replacement of RAMC01-R4SS-57S1-T65NNN*B/1D1/P3/A2/K1


  • Estimated Lead Time: 10 - 12
  • Shipping Weight: 10 Kg

Add to Cart:

  • Model: RAMC01-R4SS-57S1-T91NNN/1E1/P3/A16/K1
  • 7 Units in Stock


Processing Time
  • Ships in 24 hours: Processing Time is guaranteed to be shorter than 24 hours.
  • Typical Processing Time: 3 - 12 days

We ship to over 200 countries worldwide!