Part Number: EJA118W-EMSA4FB-AA03-92DJ/FU1/HE/A/D1
Model and Suffix Codes
Model: EJA118W - Diaphragm sealed differential pressure transmitter (Flush diaphragm type)
Output Signal: E - 4 to 20 mA DC with digital communication (HART protocol, see IM 01C22T01-01E)
Measurement span (capsule): M - 2.5 to 100 kPa {250 to 10000 mmH2O}
Wetted parts material: S - [Diaphragm] JIS SUS316L; [Others] JIS SUS316L
Process flange rating: A4 - ANSI class 600
Process flange size/material: F - 3-inch (80 mm) / JIS SUS316
Cover flange bolts material: B - JIS SUS630
Fill fluid: -A - For general use (silicone oil) [Process temp.] 10 to 250?C, [Ambient temp.] 10 to 60?C
A - Always A
Capillary length (m): 03 - 3 m
Installation: -9 - Horizontal impulse piping type, left side high pressure
Electrical connection: 2 -
Integral indicator: D - Digital indicator
Mounting bracket: J - JIS SUS316 2-inch pipe mounting (flat type)
Optional Codes:
/FU1: Factory Mutual (FM)
Combined FF1 and FS1
/HE: Fluoro-rubber O-ring
All O-rings of amplifier housing. Lower limit of ambient temperature : 15?C (5?F)
/A: Lightning protector
Transmitter power supply voltage: 10.5 to 32 V DC (9 to 32 V DC for FOUNDATION Fieldbus and PROFIBUS PA communication type.)
Allowable current: Max. 6000 A (1?40 s), Repeating 1000 A (1?40 s) 100 times
/D1: Calibration units
P calibration (psi unit)
NOTE:
- Applicable for Electrical connection code 2 and 7 (1/2 NPT female).
- Estimated Lead Time: 8 - 10
- Shipping Weight: 20 Kg
- Made in Japan