Part Number: 3051CD2A22A1AB4I1M5Q4Q8DZ
Ordering Information
Model: 3051C1 - Coplanar Pressure Transmitter
Measurement type: D - Differential
Pressure range: 2 - ?250 to 250 inH2O (-621,60 to 621,60 mbar)
Transmitter output: A2 - 4-20 mA with Digital Signal Based on HART Protocol
Materials of construction: 2 -
[Process flange type] Coplanar;
[Flange material] SST;
[Drain/vent] SST
Isolating diaphragm: 23 - 316L SST
O-ring: A - Glass-filled PTFE
Sensor fill fluid: 1 - Silicone
Housing material: A - Aluminium; 1/2-14 NPT [Conduit entry size]
Mounting bracket4: B4 - Coplanar flange bracket, all SST, 2-in. pipe and panel
Product certifications: I15- ATEX Intrinsic Safety and Dust
Display and interface options: M5 - LCD Display
Calibration certificate: Q4 - Calibration Certificate
Material traceability certification: Q8 - Material Traceability Certification per EN 10204 3.1
Configuration buttons: DZ6 - Digital Zero Trim
NOTE:
- Select Configuration Buttons (option code D4 or DZ) or Local Operator Interface (option code M4) if local configuration buttons are required.
- Option HR5 configures the HART output to HART Revision 5. Option HR7 configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 or 7 if desired. HART Revision 5 is the default HART output.
- Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
- Panel mounting bolts are not supplied.
- Dust approval not applicable to Output Code X. See ?IEC 62591 (WirelessHART Protocol)? on page 62 for wireless approvals.
- Only available with HART 4-20 mA Output (output code A) and Wireless Output (output code X)
Estimated Lead Time: 3 - 4 Shipping Weight: 6 Kg